Tolerance-Dependent Inspection Disagreement Between a Fixed CMM and a Portable Articulated-Arm CMM
固定式坐标测量机和便携式铰接臂式坐标测量机之间与公差相关的检查不一致
Md Manjurul Ahsan、Hamidreza Samadi、Shivakumar Raman · arXiv:2608.21404 · 2026-08-08 · cs.RO
固定坐标测量机 (CMM) 和便携式铰接臂 CMM 通常被分配到相同的检测任务,但它们的标称精度规格并不表明更换仪器是否会保留零件的配置。问题不仅仅是两个结果相差有多大,而是这种差异是否超出了公差边界。我们通过在标称 20 °C 和 30 °C 条件下记录的圆柱形、立方体和球形特征的测量结果来研究这个问题。重复记录和没有足够采集信息的两个粗糙度轮廓被删除,留下六维和四形临
中文为机器翻译节选,以英文原文为准。
English abstract
Fixed coordinate measuring machines (CMMs) and portable articulated-arm CMMs are often assigned to the same inspection task, but their nominal accuracy specifications do not show whether a change of instrument will preserve the disposition of a part. The question is not simply how far the two results differ, but whether that difference crosses the tolerance boundary. We examined this issue with recorded measurements of cylindrical, cubic, and spherical features under nominal 20 °C and 30 °C conditions. Repeated records and two roughness profiles without sufficient acquisition information were removed, leaving six dimensional and four form profiles. For each dimensional feature, the distances of the two system means from nominal define the exact tolerance interval in which the systems receive opposite direct labels. The fixed-CMM stream was approximately 11.2 μm higher than the…