Contact-Aware Impedance Controller for Robot-Assisted Ultrasound Imaging

用于机器人辅助超声成像的接触感知阻抗控制器

MD Miraj Arefin、M Efe Tiryaki · arXiv:2609.34400 · 2026-09-28 · cs.RO

论文自动收录 · 未精读PDF ↗arXiv 原文 ↗
壹摘要

安全的机器人辅助超声成像需要一个可靠的控制器,能够检测和定位探头与组织的相互作用。在本文中,我们提出了一种基于 B 型超声图像的接触感知方法和用于机器人超声成像的接触感知阻抗控制器。所提出的方法独立于力测量来检测声学接触,从而实现接触调节力/扭矩去皮以减少残余扳手偏差。在接触过程中,该方法不断估计沿弯曲探头表面的有效接触位置,并用它来更新控制器交互框架,从而实现物理的视觉伺服

中文为机器翻译节选,以英文原文为准。

English abstract

Safe robot-assisted ultrasound imaging requires a reliable controller able to detect and localize probe--tissue interaction. In this paper, we present a B-mode ultrasound image-based contact perception method and a contact-aware impedance controller for robotic ultrasound imaging. The proposed method detects acoustic contact independently of force measurements, enabling contact-conditioned force/torque taring to reduce residual wrench bias. During contact, the method continuously estimates the effective contact location along the curved probe surface and uses it to update the controller interaction frame, enabling visual servoing of the physical probe--tissue contact point during imaging. Experiments on an agar phantom demonstrated a contact-localization RMSE of 1.46 pm 0.14~mm over probe roll angles from -15^∘ to 15^∘. During static rolling,…

贰引用
MD Miraj Arefin、M Efe Tiryaki. Contact-Aware Impedance Controller for Robot-Assisted Ultrasound Imaging. arXiv:2609.34400 (2026-09-28). https://arxiv.org/abs/2609.34400v1
叁同分类新篇