Robotic Optical Coherence Tomography-Guided Geometric Modeling of Soft Tissue: 3D Representations for Data-Driven Closed-Loop Shape Control
机器人光学相干断层扫描引导软组织几何建模:数据驱动闭环形状控制的 3D 表示
Chaoyu Zhang、Guangshen Ma、Mark Draelos · arXiv:2610.32961 · 2026-10-23 · cs.RO
在医疗机器人技术中,数据驱动的软组织形状控制需要通过连续的物理相互作用使组织变形为所需的形态。这一挑战在微尺度操纵中尤为重要,因为局部变形难以观察、表示和控制,而基于物理的模型计算成本高昂且难以适应现实环境。光学相干断层扫描 (OCT) 提供组织变形的高分辨率体积感知,但目标条件控制需要有效表示观察到的和期望的组织状态。在这项工作中,我们介绍了
中文为机器翻译节选,以英文原文为准。
English abstract
In medical robotics, data-driven soft-tissue shape control requires deforming tissue toward desired morphologies through sequential physical interactions. This challenge is particularly important in microscale manipulation, where localized deformation is difficult to observe, represent, and control, while physics-based models can be computationally expensive and difficult to adapt to realistic environments. Optical coherence tomography (OCT) provides high-resolution volumetric perception of tissue deformation, but target-conditioned control requires effective representations of both observed and desired tissue states. In this work, we introduce an OCT-guided data-driven framework for tissue shape control, learned from user-guided demonstrations and executed with closed-loop OCT feedback. We study full-volume, tissue-masked sparse-volume, and voxelized point-cloud representations, with…